Engineering Solutions Manual — Introduction To Food

$$\boxedt \approx 2.28 \text hours$$ Problem 5.14: Heat Exchanger Design (Pasteurizer) Given: Milk ($c_p = 3.9 \text kJ/kg\cdot\textK$) flows at 0.5 kg/s from 4°C to 72°C. Hot water ($c_p = 4.18 \text kJ/kg\cdot\textK$) enters at 85°C, exits at 50°C. Overall $U = 1500 \text W/m^2\cdot\textK$. Find area for counter-flow.

Not required here.

$$Q = \dotm_w (4180)(85 - 50) \Rightarrow \dotm_w = \frac1326004180 \times 35 = 0.906 \text kg/s$$ Introduction To Food Engineering Solutions Manual

$$\fracT_0 - T_\inftyT_i - T_\infty = \frac119 - 12125 - 121 = \frac-2-96 = 0.02083$$ $$\boxedt \approx 2

$$Q = U A \Delta T_lm \Rightarrow A = \fracQU \Delta T_lm = \frac1326001500 \times 26.13$$ $$A = \frac13260039195 = 3.383 \text m^2$$ Introduction To Food Engineering Solutions Manual